BS 5266-1 • DESIGN • INSTALLATION • MAINTENANCE

Emergency Lighting Installation UK — Design, Installation & MaintenanceEscape route design • Photometric calculations • Commissioned and certified • North West based

FireJet designs, installs and maintains emergency lighting systems to BS 5266-1. Whether you are fitting out a new premises, refurbishing an existing one, or replacing a system that no longer holds its duration, our engineers take it from survey and light-level design through to installation, commissioning and certification.

We work on self-contained, central battery and addressable self-test systems, install into occupied buildings without closing them down, and stay on afterwards to keep the system tested and compliant.

  • Free site survey and BS 5266-1 light-level design
  • Escape route, open area and high-risk task area lighting
  • Self-contained, central battery and addressable systems
  • Installation phased around your operation
  • Commissioning certificate, as-fitted drawings and O&M file
  • Fixed-price quotation — no hidden extras

What We Deliver

One contractor for the whole lifecycle of the system — from drawing board to annual test.

DesignEscape routes plotted and light levels calculated before installation
InstallQualified electricians installing to the design and commissioning every circuit
CertifyBS 5266-1 commissioning certificate, as-fitted drawings and O&M file
MaintainMonthly function and annual 3-hour duration tests scheduled automatically

BASED IN CHORLEY, LANCASHIRE PR7 • NORTH WEST COVERAGE WITH LOCAL ENGINEERS • NATIONWIDE INSTALLATION

DESIGN • INSTALLATION • MAINTENANCE

Three Stages, One Contractor

Most emergency lighting problems trace back to the design: fittings replaced in the same positions, escape routes that were never re-plotted, and light levels that were never calculated. We handle design, installation and maintenance as one job so the system that gets installed is the system that was designed — and the one that gets maintained to the same standard.

Design & Specification

Escape routes plotted, light levels calculated, fittings positioned and specified before anyone drills a hole.

  • Escape route and open area lighting design to BS 5266-1
  • Room-by-room risk review to place each luminaire correctly
  • Photometric light-level calculations and spacing plans
  • Self-contained vs central battery vs addressable recommendation
  • Maintained / non-maintained selection per location
  • Full specification, drawings and cable routes for tender

Installation & Commissioning

Qualified electricians install to the design, commission every circuit and hand over with certification.

  • Installation by qualified, electrically competent engineers
  • New circuits wired to BS 7671 and tested before energising
  • Work phased around your operation — evenings and weekends if needed
  • Commissioning of every luminaire, exit sign and battery circuit
  • As-fitted drawings and a full operation & maintenance file
  • BS 5266-1 commissioning certificate issued at handover

Maintenance & Testing

The ongoing BS 5266-1 regime — scheduled, documented and never left to lapse.

  • Monthly function tests carried out or set up for auto-test
  • Annual 3-hour duration test on mains failure
  • Emergency lighting log book maintained at every visit
  • Failed lamps, batteries and fittings rectified on site
  • Spares and end-of-life fittings held for your system
  • Automatic scheduling so no test date is ever missed

When You Need a New or Upgraded System

Emergency lighting installation covers more than new buildings. Most of the work we quote is replacing, extending or re-designing systems that no longer match the building they are in.

New build or fit-out

The premises is being built, converted or fitted out and needs a compliant system designed from scratch rather than retro-fitted later.

Refurbishment or change of layout

Walls, rooms or escape routes have moved, so the existing lighting no longer covers the routes people actually use.

Change of use or occupancy

A unit becomes a restaurant, a shop becomes a gym, or occupancy rises — all of which change the emergency lighting requirement.

Failed 3-hour duration test

Fittings and batteries that no longer hold their rated duration need replacing or the system needs re-designing.

Escape routes extended

New stairwells, corridors, external paths or additional floors leave sections of the escape route unlit.

Fittings at end of life

Fluorescent emergency fittings and ageing battery packs are unreliable and increasingly expensive to keep repairing.

LED upgrade programme

Upgrading to LED emergency luminaires cuts running costs and maintenance visits while improving reliability.

Remedial works after an inspection

A fire officer, insurer or risk assessment has identified emergency lighting deficiencies that need putting right.

Multi-site rollout

A consistent specification across several premises, installed and maintained to one standard and one schedule.

Emergency Lighting Systems We Design & Install

The right system depends on the building, not on what is easiest to fit. We will recommend the option that suits your layout, your testing capacity and your budget — and explain the trade-offs plainly.

Self-contained luminaires

Battery and charging circuit inside each fitting. Simplest to install and expand, and the most common choice for smaller and medium premises.

Central battery systems

One battery bank serving all fittings. Easier to test and monitor centrally, and well suited to larger or multi-floor buildings.

Addressable / auto-test

Fittings that self-test on a schedule and report faults back to a panel or software. Slashes manual testing time on large sites.

Maintained luminaires

Lit at all times, so they double as normal lighting. Used in cinemas, halls, plant rooms and areas occupied during a power failure.

Non-maintained luminaires

Only illuminate when the mains fails. The standard choice for corridors, offices and most escape routes.

Escape route lighting

Illuminates the path out of the building — corridors, stairs, changes of level, and the route to the final exit.

Open area / anti-panic lighting

Prevents panic in rooms over 60 m² by offering a minimum light level across the floor area.

High-risk task area lighting

Higher light levels for people working on dangerous machinery or processes who need to shut down safely before evacuating.

Illuminated exit signage

Internal and external exit signs to BS EN ISO 7010, including directional signage where the exit is not immediately visible.

How an Emergency Lighting Installation Works

Six stages from first survey to an ongoing testing schedule.

01

Free Site Survey

We walk the building with you, review the layout and occupancy, and identify every escape route, open area and high-risk location.

02

Design & Specification

We plot escape routes, calculate light levels and position each luminaire, then specify the system type, fitting schedule and cable routes.

03

Fixed-Price Quotation

A written fixed-price quote broken down by scope — design, supply, installation, commissioning and certification. Priced on labour, cable runs and site conditions rather than a flat rate per fitting, so no hidden extras.

04

Installation

Our engineers install to the design, phased around your operation. Occupied buildings are worked in sections, out of hours where needed.

05

Commissioning & Certification

Every luminaire, exit sign and circuit is commissioned and tested. You receive drawings, the commissioning certificate and an O&M file.

06

Ongoing Maintenance

We schedule the monthly and annual tests automatically and maintain your log book, so compliance continues long after handover.

Premises We Install Into

We install emergency lighting across every sector, from single-office fit-outs to multi-site rollouts. If the building has an escape route, it has an emergency lighting requirement.

Offices & commercial premises
Warehouses & distribution centres
Factories & industrial units
Retail units & shopping centres
Restaurants, bars & hotels
Schools, colleges & universities
Care homes & sheltered housing
HMOs & communal residential
Surgeries & healthcare premises
Sports halls & leisure centres
Multi-storey car parks
New-build fit-outs & refurbishments

Installed to the Right Standards

BS 5266-1:2025

The current UK code of practice for the design, installation, commissioning and maintenance of emergency lighting. Published October 2025 and superseding the 2016 edition, it introduces mandatory photometric verification every five years and widens the scope to cover local area lighting and standby lighting alongside escape lighting.

BS EN 50172

Escape lighting systems for premises with public or communal access.

BS EN 1838:2024

The light levels the design must achieve — a minimum of 1 lux across the full width of the escape route, 0.5 lux at floor level in open areas, and 5 lux vertical at points of emphasis such as call points and firefighting equipment. Borrowed light from other sources cannot be relied upon.

BS 7671

Fixed wiring installation and testing for the new circuits.

NORTH WEST COVERAGE

Emergency Lighting Installation Across the North West

Our base is in Chorley, Lancashire, so North West work gets the fastest response — local engineers, quicker mobilisation on remedial works and no travel loading on the quotation. Select your town for local service details.

Also Installing Nationwide

Don't see your town? We install across the whole of the UK — view all service areas or contact us.

Already Have a System? You Probably Need Testing, Not Installation

If your emergency lighting is installed and working, the legal requirement is to keep it tested and documented — a monthly function test and an annual 3-hour duration test under BS 5266-1. That is a different service from installation, and it is what most existing buildings need.

Installation — this page

A new system, a system being extended or replaced, or fittings at end of life. Includes design, specification, commissioning and certification.

YOU ARE HERE

Testing & Maintenance →

Annual 3-hour duration tests, monthly function tests, certificates and log book updates for an existing system. From £219 + VAT.

GO TO TESTING PAGE →

4.9★ Google Rated

247 REVIEWS

BAFE Accredited

INDEPENDENT CERTIFIED

24hr Response

SAME-DAY CALL-OUT

12,000+ Inspections

COMPLETED

FREE • NO OBLIGATION • 24HR RESPONSE

Book a Free Emergency Lighting Survey

Free site survey, BS 5266-1 design and a written fixed-price quotation. North West based with engineers nationwide — call for a survey date.

Free, no-obligation site survey
Fixed-price quotes — no hidden charges
Compliance certificates issued same day
Same-day emergency call-out available

Request a Callback

Fill in the form — we'll call you back within 24 hours.

Emergency Lighting Installation FAQs

Common questions about design, cost, standards, working in occupied buildings and certification.

How much does emergency lighting installation cost?+

There is no standard rate per fitting, because installation is priced on labour and that is driven by the building. The biggest single factor is the distance cable has to run between each luminaire, and how practical that route is — surface trunking, above ceilings, through fire compartments, below floor or through occupied areas. On top of that we take account of the number and type of luminaires, whether the system is self-contained, central battery or addressable, whether new circuits or a distribution board are needed, whether the building stays occupied during the works, and any out-of-hours or weekend working. Because those vary so much from site to site, a per-point figure would be misleading. Instead we carry out a free site survey and provide a written fixed-price quotation broken down by scope — design, supply, installation, commissioning and certification — so you can see exactly what you are paying for.

Do I legally need emergency lighting in my building?+

Under the Regulatory Reform (Fire Safety) Order 2005 the responsible person must keep escape routes adequately lit and maintain emergency lighting in efficient working order. BS 5266-1 is the code of practice that sets out what that means in practice — escape route lighting, open area (anti-panic) lighting and, in some cases, high-risk task area lighting. It applies to virtually all non-domestic premises, plus the communal areas of residential buildings. A properly designed and documented system is how you evidence compliance.

What standard do you design and install to?+

We design, install and commission to BS 5266-1, the UK code of practice for emergency lighting, together with BS EN 50172 for escape lighting systems and BS EN 1838 for the light-level requirements. Fixed wiring is installed and tested to BS 7671, and new-build work is coordinated with Approved Document B. Our commissioning certificate confirms the system has been installed and verified against the design.

What is the difference between maintained and non-maintained emergency lighting?+

A maintained luminaire is lit all the time and continues to work when the mains fails — it doubles as ordinary lighting, which is why it suits cinemas, halls, plant rooms and anywhere occupied during a power cut. A non-maintained luminaire stays off and only illuminates on loss of mains supply, which is standard for corridors, offices and most escape routes. Most buildings use a mix of both, and choosing correctly is part of the design rather than something to decide on site.

Can you install emergency lighting in an occupied building?+

Yes, and most of our installation work is in buildings that stay open. We phase the work in sections so escape routes remain covered and usable throughout, and we work evenings, nights or weekends where noise, access or trading hours require it. We will agree a phasing plan and a programme before starting so your operation knows exactly what is happening and when.

Do you provide drawings and certification?+

Yes. You receive the design drawings and fitting schedule, as-fitted drawings showing what was actually installed and where, a BS 5266-1 commissioning certificate, test results for the new circuits, and an operation and maintenance file. These are the documents a fire officer, insurer or auditor will ask to see, and they are what make a system demonstrably compliant rather than just present.

Can you upgrade part of an existing system rather than replacing it all?+

Yes. Phased upgrades are common — replacing failed or end-of-life fittings floor by floor, converting a central battery system to addressable self-contained units, or swapping fluorescent emergency fittings for LED. We will tell you honestly where a partial upgrade works well and where the existing infrastructure is too poor to build on, rather than selling a full replacement you do not need.

How long does an emergency lighting installation take?+

It depends on scale and access. A small single-floor premises can usually be completed in a day or two once the design is approved. Larger buildings, central battery systems and multi-phase fit-outs run for weeks and are programmed in sections. We give you a realistic programme with the quotation rather than an optimistic figure, and we keep to agreed dates.

What is photometric design and why does it matter?+

Photometric design means calculating the actual light level each luminaire will produce along the escape route and at floor level, then positioning fittings so the required levels are met — rather than simply replacing old fittings in the same spots. It matters more than ever under BS 5266-1:2025, which introduces mandatory photometric verification every five years. In practice that means measured light levels are checked with calibrated equipment against the original design, with the results recorded in the log book. That check is only possible if there was a documented design to begin with, which is the difference between a system that passes a duration test and one that is genuinely adequate.

Do you install emergency lighting nationwide or only in the North West?+

We install nationwide, with our base in Chorley, Lancashire and engineers covering the North West, Yorkshire, the Midlands, the South Coast and London. For North West work in particular we are local — which means faster site surveys, quicker mobilisation on remedial works and no travel loading on the quotation. Wherever your premises is, we can assign a local engineer and keep a consistent specification across multiple sites.

Can you take over maintenance of the system once it is installed?+

Yes, and it is how most of our installation customers work. We schedule the monthly function test and the annual 3-hour duration test automatically, maintain the log book, rectify failed fittings and hold relevant spares for your system so you are not waiting on parts during a compliance deadline. We also take over testing and maintenance of systems installed by other contractors.

Is emergency lighting required in HMOs and rented property?+

In most cases, yes for the common parts. The communal areas of an HMO or block of flats — corridors, stairwells and shared exits — fall within the Regulatory Reform (Fire Safety) Order 2005, so they need adequate emergency lighting, usually with a documented testing regime. Requirements vary with building height, layout and licensing conditions, so it is worth having the specific property assessed rather than working from a general rule.